BIOHAZARD The BIOHAZARD warning label should be attached to device prior to first use with biological material.
Before creating any maintenance on tool it is important to thoroughly disinfect all probably polluted portion. Ahead of the instrument is completely removed from laboratory for discretion or maintenance, it should be decontaminated. Decontamination needs to be sang by authorised well trained employees only, watching all necessary protection precautions. Instruments as came back have to be combined with a decontamination certificate done by the accountable laboratory management. If a decontamination certification is not provided, the going back lab are going to be accountable for charges resulting from non-acceptance associated with the tool from the servicing hub, or from authoritys treatments.
Contents 1 2 3 4 5
INTRODUCTION RUNNING TREATMENTS CLEANSING AND SERVICING PROBLEM SOLVING CONTACT INFO
1.1 Solutions 1.1.1 Intended Need 1.1.2 Overview with the Tool
1.3 Alert Marks 1.3.1 Safety Signs 1.3.2 Safety Terms And Conditions
1.4 Protection Safety Measures
1.5 Setup 1.5.1 Unpacking 1.5.2 Installation/Preparation 1.5.3 Keypad Classification
1.7 Getting Started 1.7.1 ready Date/Time and lab label 1.7.2 Printer Set Up
2.1 Standard Picks 2.1.1 Flowcell Setup 2.1.2 Light Warm-up and Lamp Saver 2.1.3 Outside Ports 2.1.4 Serial Port 2.1.5 Computer Connections 2.1.6 Error Messages with all the Parallel or Serial slots 2.1.7 Products of Measurement 2.1.8 Getting Into Labels 2.1.9 Ranges and Controls 2.1.10 Research 2.1.11 Blanking 2.1.12 Checking Out Products 2.1.13 Bichromatic Procedure (Differential Filter)
14 14 15 15 15 16 16 16 17 17 20 21 21 22
2.2 formula tools 2.2.1 Absorbance function 2.2.2 solitary Standard setting 2.2.3 aspect function 2.2.4 Multi-point Mode 2.2.5 price Mode
22 22 23 25 25 27
2.3 secured exams 2.3.1 Recalling a retained examination 2.3.2 Listing kept examinations 2.3.3 Removing a test 2.3.4 Modifying a test 2.3.5 making use of WORKLIST
31 32 32 32 32 33
2.4 Special Functions 2.4.1 Self-Check 2.4.2 Flags and Mistake Information
1 INTRODUCTION 1.1
1.1.1 Planned utilize this device is intended to be familiar with read and determine the results of in-vitro medical symptomatic assays, also almost every other program needing absorbance or focus indication at or close to the readily available wave-lengths. This general-purpose device is intended to be employed by laboratory professionals capable of choosing the suitable qualities and choices for each specific clinical application. 1.1.2 Summary of the Instrument HUMALYZER 3000 is perfect for the examination of Biochemistry chemical Immuno and Drug degrees from person serum, plasma, or urine. A removable Flowcell installs inside study well to provide incredibly fast liquid sampling with low carryover. An integrated machine pump and an external waste bottles with stage feeling is sup-plied standard. As soon as the Flowcell is taken away, the tool allows regular 12 mm circular pipes along with 1 cm square cuvettes. The appearance of the device consists of many attributes to reduce driver error, such as for example secure factory calibration, automatic zeroing, full operator prompting, step-by-step labelling, pre-programmed data, aesthetic and clear comments, flags and error messages, and very little repair requirements. The functioning modes become: Absorbance setting The HUMALYZER 3000 checks out monochromatic or bichromatic differential absorbances at user-selected wavelengths. Standards form Reports density centered on a single regular concentration. Speed form states concentrations either on the basis of the normal absorbance each minute multiplied by a person furnished factor (Rates by Factor), or on the basis of the absorbance a minute of a standard (Rate by traditional). A fixed-time kinetic mode calculates predicated on ?absorbance over a specific period. The interest rate form includes a Batch option that enables kinetic assays to-be run at the same time. Factor setting Research levels by multiplying absorbances by a specific aspect. Multi-point Mode Reports density or percent absorbances according to the point-to-point connection as high as seven user-entered requirements. Inside the element and standards methods, differential trials (against sample blanks) tend to be supported. escort Memphis Examination parameters, and regular shape include stored in memories for after remember. The HumaLyzer 3000 shop around 120 exams in memory are remembered for later need. Furthermore, it will shop 512 individual outcomes, 512 Control information, 20 people on Worklist, and 15 exams per individual. 1.2